Authorized Navien dealer
Navien dealer in Pickering — boilers, combi boilers & tankless for Toronto homes
Keep the comfort of hydronic heat with a properly planned Navien system. Climate Experts serves Pickering, Durham Region and Toronto with heating boilers, combi boilers and tankless water heaters, including older radiator homes and renovation projects where piping and controls need careful attention.
- Locally owned since 2012
- Emergency service within 24 hours
- Financing available
Get your free quote
Share a few details about your home. We will arrange an assessment and a clear, written quote.
Prefer to talk?
905-492-7171
Navien equipment: compare the system, not just the badge
These manufacturer-published families are a starting point for a proposal. We confirm Canadian distributor availability, the exact model and capacity, and the equipment we recommend for your home before ordering.
NFB-H heating boilers
Climate Experts compares the NFB-H minimum firing rate with the smallest heating zone and its maximum heating output with the home’s heat loss. If an indirect tank is included, we plan tank recovery, priority control and pump connections alongside the radiator or floor circuits.
Read specifications, model data and selection notes
| Controls | Setup Wizard/click-wheel display; powered connections for three zone valves or pumps; boiler-pump control. |
|---|---|
| Limited warranty — conditions apply | Single-family residential: parts5 years; labour1 year subject to prior authorization/allowance; heat exchanger customer contribution0% years1–12,50% year13,60%14,70%15. Commercial:parts3 years/HX10 years/labour1 year. Licensed installation, original installation site, authorized supply, maintenance/water-quality and other certificate conditions apply. |
NFB-175H
| Model | NFB-175H |
|---|---|
| Heating input, minimum–maximum (BTU/h) | 13300 – 175000 |
| Doe heating capacity BTU/h | 160000 |
| Net ahri water BTU/h | 140000 |
| AFUE (%) | 95 |
| Dimensions in W H D |
|
| Electrical | 120VAC60Hz; less than15A |
| Application | Space heat; DHW via separate indirect tank. |
NFB-200H
| Model | NFB-200H |
|---|---|
| Heating input, minimum–maximum (BTU/h) | 13300 – 199900 |
| Doe heating capacity BTU/h | 183000 |
| Net ahri water BTU/h | 159000 |
| AFUE (%) | 95 |
| Dimensions in W H D |
|
| Electrical | 120VAC60Hz; less than15A |
| Application | Space heat; DHW via separate indirect tank. |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
NHB-H heating boilers
For a compact NHB-H installation, Climate Experts checks both wall space and the room needed for piping and service. We compare minimum firing input with small zone calls and confirm that the pump and control layout can provide the flow and temperature required by the existing emitters.
Read specifications, model data and selection notes
| Controls | Boiler-pump control plus three zone valves, three zone pumps, or two zone pumps and indirect pump; Setup Wizard. |
|---|---|
| Limited warranty — conditions apply | Single-family residential parts5 years/labour1 year. Residential heat-exchanger schedule: customer contribution0% years1–10,30%11,40%12,50%13,60%14,70%15. Commercial schedule differs. Licensed installation, original site, authorized supply, maintenance and warranty service procedures apply. |
NHB-150H
| Model | NHB-150H |
|---|---|
| Heating input, minimum–maximum (BTU/h) | 10000 – 150000 |
| Doe heating capacity BTU/h | 138000 |
| Net ahri water BTU/h | 120000 |
| AFUE (%) | 95 |
| Dimensions in W H D |
|
| Electrical | 120VAC60Hz; less than10A |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
NCB-H combi boilers
Climate Experts treats the NCB-240/110H heating and hot-water ratings separately. We check the home against its102,000BTU/h published heating capacity and compare simultaneous fixtures with flow at the required winter temperature rise, then explain how domestic-water priority affects a heating call.
Read specifications, model data and selection notes
| Controls | Setup Wizard; three zone-pump/zone-valve powered connections; outdoor reset; DHW priority. |
|---|---|
| Limited warranty — conditions apply | Single-family residential: heat exchanger10 years,parts5 years,labour1 year. Application restrictions and full certificate apply. |
NCB-240/110H
| Model | NCB-240/110H |
|---|---|
| Heating input, minimum–maximum (BTU/h) | 13000 – 110000 |
| Domestic hot-water input, minimum–maximum (BTU/h) | 13000 – 199900 |
| Doe heating capacity BTU/h | 102000 |
| Net ahri water BTU/h | 89000 |
| AFUE (%) | 95 |
| Domestic hot water US gpm by temperature rise F |
|
| Dimensions in W H D |
|
| Electrical | 120VAC60Hz; up to15A |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
NPE-2 tankless water heaters
Climate Experts starts NPE selection with winter inlet-water temperature and overlapping showers or fixtures. We then review the gas line, vent route and recirculation loop, including how its controls limit unnecessary operation; a headline maximum flow at a low temperature rise does not describe every household’s winter delivery.
Read specifications, model data and selection notes
| Controls | A2 incorporates buffer tank/recirculation pump and HotButton controls; optional recirculation mode has different flow activation and energy consumption. |
|---|---|
| Limited warranty — conditions apply | Residential standard/controlled recirculation: heat exchanger15 years,parts5,labour1. Residential uncontrolled recirculation: heat exchanger5,parts3,labour1. Commercial/combi conditions differ. Do not transfer A2 recirculation hardware or warranty assumptions to S2. |
NPE-240A2
| Model | NPE-240A2 |
|---|---|
| Domestic hot-water input, minimum–maximum (BTU/h) | 13300 – 199900 |
| Uef NG LP | 0.95 |
| Domestic hot water US gpm by temperature rise F |
|
| Dimensions in W H D |
|
| Electrical | 120VAC60Hz;200W(max2A),350W(max4A) with external pump |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
Published ratings apply to particular models and test conditions. Your Climate Experts proposal identifies the selected equipment and installation requirements; we confirm the applicable Canadian specifications before ordering.
Choosing Navien for your home
Navien boiler and tankless work requires more than swapping a wall-hung appliance. We assess the heating load, hot-water demand, existing radiators or radiant loops and the space available for piping. For an older Toronto home, keeping the comfort of hydronic heat while updating the boiler can be the right direction.
A heating-only boiler can be paired with an indirect hot-water tank; a combi boiler combines space heating and domestic hot water in one appliance. A tankless water heater serves domestic hot water rather than replacing a space-heating boiler. We explain those differences and plan zones, pumps, controls, venting, gas supply and service access around the chosen arrangement.
Before equipment is ordered
We review the heating and cooling requirements, installation access and service space. The written proposal names the equipment, controls and agreed work.
When the installation is complete
We commission the system, explain the controls and maintenance, and document the applicable registration and warranty details.
Get a clear, written quote for your Navien system.
Free in-home assessment · Financing available through Financeit · Ask us about current rebates and manufacturer offers.
Navien warranty: parts, equipment and labour
Coverage depends on the exact equipment, Canadian certificate, installation and registration. Parts, heat exchangers, equipment replacement and labour are separate benefits. Read the family-specific terms above; our written proposal identifies the coverage for your selected system.

Current Navien offers and rebate planning
Manufacturer promotions change by model, location and dealer participation. Ask us to check any current Canadian offer against your exact system and purchase date; we show confirmed eligibility and expiry dates in the written proposal.
This dated manufacturer offer has ended or has not yet started. Contact us for current Canadian offers.
For heat-pump projects, review Ontario rebate planning before purchase. Program eligibility is separate from a manufacturer promotion.
Manufacturer information checked October 5, 2026.
Your Navien system, supported by a local team
Pickering roots. Toronto and Durham service.
Climate Experts was founded by Cody Johnson in 2012. Cody brings 20 years of HVAC experience, with G2, 313D and 308R licences. Our shop is at Unit 13, 905 Dillingham Rd, Pickering. Office hours are Monday–Friday, 8 a.m.–5 p.m., with emergency service evenings and weekends.
Explore our team, our work and customer reviews.
Equipment information from your local team
Stay with Climate Experts while you compare the equipment. We explain the proposed models, installation scope and maintenance, and provide the applicable product and warranty documents for your selected system.
Speak with our local Navien teamBoiler installation and service
Older Toronto boiler and radiator heating
Tankless hot-water planning
Our customers. Our community.
Proud of our work. Grateful for your reviews.
Our five-star customer reviews are a source of pride for Climate Experts. We want the experience behind our name to reflect the care we put into the work.
Navien questions homeowners ask
Still have a question?
Call 905-492-7171 and tell us what you need. Our team will explain the next step and confirm availability.
Can a Navien boiler work with my older Toronto radiators?
We assess the existing radiators, piping, heat loss and water-temperature requirements. The distribution can often remain, while the new boiler, pumps and controls are planned around it.
Should I choose a combi boiler or a boiler with an indirect tank?
A combi saves appliance space, while a separate tank can suit different hot-water demands. We assess simultaneous showers and fixtures as well as the heating requirement.
Does a tankless water heater replace my heating boiler?
A domestic tankless unit and a space-heating boiler serve different purposes. We select an approved arrangement for the application rather than treating them as interchangeable.
What maintenance does Navien equipment need?
The service plan follows the model manual and water conditions, including cleaning, water-quality checks and descaling where required. Maintenance supports efficient operation and warranty compliance.
What is included in a Navien installation quote?
The quote identifies the selected equipment and controls, installation scope, applicable warranty and any confirmed rebates. Tell us about comfort problems, planned renovations and access restrictions so those needs can be assessed before the scope is agreed.
Can you maintain my Navien system after installation?
Contact our Pickering service team for maintenance planning. The visit and schedule depend on the equipment, its condition and the manufacturer’s requirements. Maintenance 365 options can be reviewed with the specific systems you want covered.
Your next step
Talk to a Climate Expert about Navien
Tell us where you live, what equipment you have and what you want to improve. We will discuss the assessment and system options for your home.
Emergency? Call 905-492-7171. Emergency service is available after hours, evenings and weekends.