King Home systems · Pickering, Durham & Toronto
King Home ductless, air conditioners & heat pumps in Pickering and Toronto
Climate Experts sells and installs King Home ductless systems, central air conditioners and heat pumps across Pickering, Durham Region and Toronto. We help you compare room-by-room comfort with a ducted system, then size and plan the equipment around your home, existing heating and installation access.
- Locally owned since 2012
- Emergency service within 24 hours
- Financing available
Get your free quote
Share a few details about your home. We will arrange an assessment and a clear, written quote.
Prefer to talk?
905-492-7171
King Home equipment: choose the complete system
These current manufacturer-published families help you compare options. We confirm the exact Canadian models, distributor availability and equipment recommended for your home before ordering.
R32 Ultranixx cold-climate heat pump
Climate Experts selects Ultranixx from the rated outdoor and indoor pair, then compares its heating output at−15°C with the home’s heat loss. We also check the remaining load at the local design temperature, airflow and the backup-control sequence before deciding how much winter heating the system will supply.
Read specifications, model data and selection notes
| Controls | Confirm selected installation manual for24V/RS485 wiring mode; family page describes2/4-wire RS485 heat-pump operation. |
|---|---|
| Limited warranty — conditions apply | Submittals state standard7-year parts/compressor and registered12-year parts/compressor; terms apply. Labour is not established by those equipment terms. |
Model data
| Matched models outdoor indoor | KU36UXO / KD24UXI |
|---|---|
| Rated cooling BTU/h | 24000 |
| Rated heating BTU/h at47F | 25000 |
| Rated heating BTU/h at17F | 20600 |
| Rated heating BTU/h at5F minus15C | 24000 |
| SEER2 | 18 |
| Electrical | 208–230V1Ph60Hz |
| Heating operating range C | -30 – 24 |
| Cooling operating range C | -15 – 54 |
| HSPF2 | 10 |
| Outdoor MCA A | 21 |
| Outdoor MOP A | 25 |
Model data
| Matched models outdoor indoor | KU36UXO / KD36UXI |
|---|---|
| Rated cooling BTU/h | 34000 |
| Rated heating BTU/h at47F | 34000 |
| Rated heating BTU/h at17F | 28200 |
| Rated heating BTU/h at5F minus15C | 34000 |
| SEER2 | 16 |
| Electrical | 208–230V1Ph60Hz |
| Heating operating range C | -30 – 24 |
| Cooling operating range C | -15 – 54 |
| HSPF2 | 9.5 |
| Outdoor MCA A | 27 |
| Outdoor MOP A | 30 |
Model data
| Matched models outdoor indoor | KU60UXO / KD48UXI |
|---|---|
| Rated cooling BTU/h | 48000 |
| Rated heating BTU/h at47F | 48000 |
| Rated heating BTU/h at17F | 39500 |
| Rated heating BTU/h at5F minus15C | 48000 |
| SEER2 | 17 |
| Electrical | 208–230V1Ph60Hz |
| Heating operating range C | -30 – 24 |
| Cooling operating range C | -15 – 54 |
| HSPF2 | 9.5 |
| Outdoor MCA A | 39 |
| Outdoor MOP A | 45 |
Model data
| Matched models outdoor indoor | KU60UXO / KD60UXI |
|---|---|
| Rated cooling BTU/h | 53000 |
| Rated heating BTU/h at47F | 54000 |
| Rated heating BTU/h at17F | 45000 |
| Rated heating BTU/h at5F minus15C | 54000 |
| SEER2 | 18.5 |
| Electrical | 208–230V1Ph60Hz |
| Heating operating range C | -30 – 24 |
| Cooling operating range C | -15 – 54 |
| HSPF2 | 10.5 |
| Outdoor MCA A | 39 |
| Outdoor MOP A | 45 |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
Discuss R32 Ultranixx cold-climate heat pump with Climate Experts
R32 Ultranixx Eco ducted heat pump
Climate Experts compares Eco’s published winter output with the home’s load and plans supplemental heat for conditions beyond its heating range. We confirm whether an air handler or furnace-and-coil arrangement suits the ducts, electrical capacity and controls, and use only the selected combination’s efficiency rating.
Read specifications, model data and selection notes
| Controls | RS485 or universal24V; multi-position air handlers. |
|---|---|
| Limited warranty — conditions apply | Brochure lists12-year residential parts/compressor on registered models; commercial and all qualification terms require selected certificate. Labour separate. |
KD30UXO
| Outdoor | KD30UXO |
|---|---|
| Indoor | KD24UXI |
| Rated cooling at 95°F (BTU/h) | 24000 |
| Rated heating BTU/h at47F | 24000 |
| Rated heating BTU/h at17F | 19600 |
| Rated heating at 5°F (BTU/h) | 19000 |
| SEER2 | 18 |
| HSPF2 | 8.3 |
| Outdoor MCA A | 21 |
| Outdoor MOCP A | 25 |
| Outdoor dimensions in W D H | 36-1/4 ×14-9/16 ×29-3/8 |
| Power supply | 208–230V1Ph60Hz |
| Heating operating range C | -15 – 24 |
KD36UXO
| Outdoor | KD36UXO |
|---|---|
| Indoor | KD36UXI |
| Rated cooling at 95°F (BTU/h) | 34000 |
| Rated heating BTU/h at47F | 34000 |
| Rated heating BTU/h at17F | 27400 |
| Rated heating at 5°F (BTU/h) | 21600 |
| SEER2 | 19 |
| HSPF2 | 8.3 |
| Outdoor MCA A | 21 |
| Outdoor MOCP A | 25 |
| Outdoor dimensions in W D H | 36-1/4 ×14-9/16 ×29-3/8 |
| Power supply | 208–230V1Ph60Hz |
| Heating operating range C | -15 – 24 |
KD60UXO
| Outdoor | KD60UXO |
|---|---|
| Indoor | KD48UXI |
| Rated cooling at 95°F (BTU/h) | 48000 |
| Rated heating BTU/h at47F | 48000 |
| Rated heating BTU/h at17F | 38500 |
| Rated heating at 5°F (BTU/h) | 36000 |
| SEER2 | 19 |
| HSPF2 | 9.5 |
| Outdoor MCA A | 35 |
| Outdoor MOCP A | 40 |
| Outdoor dimensions in W D H | 35-7/16 ×13-3/8 ×49-5/8 |
| Power supply | 208–230V1Ph60Hz |
| Heating operating range C | -15 – 24 |
KD60UXO
| Outdoor | KD60UXO |
|---|---|
| Indoor | KD60UXI |
| Rated cooling at 95°F (BTU/h) | 54000 |
| Rated heating BTU/h at47F | 54000 |
| Rated heating BTU/h at17F | 43000 |
| Rated heating at 5°F (BTU/h) | 40000 |
| SEER2 | 19 |
| HSPF2 | 9.5 |
| Outdoor MCA A | 35 |
| Outdoor MOCP A | 40 |
| Outdoor dimensions in W D H | 35-7/16 ×13-3/8 ×49-5/8 |
| Power supply | 208–230V1Ph60Hz |
| Heating operating range C | -15 – 24 |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
Discuss R32 Ultranixx Eco ducted heat pump with Climate Experts
R32 single-zone ductless mini-splits
Climate Experts sizes each single-zone system for the room’s heat gain and heat loss, then checks the chosen series at winter temperatures. We place the indoor unit for useful air distribution and service access and plan the drain and refrigerant route; different9k or12k series can have very different cold-weather output.
Read specifications, model data and selection notes
| Controls | Remote supplied on published family material; Wi-Fi/app controls. Wall controller is optional; verify accessory against selected model. |
|---|---|
| Limited warranty — conditions apply | July2026 series sheets state12-year residential parts/compressor on registered models; commercial wording5/7 years is not resolved here. Full certificate required; no manufacturer labour inferred. |
Airy
KW09XQ29S1DO
| Outdoor | KW09XQ29S1DO |
|---|---|
| Indoor | KW09XQ29S1DI |
| Rated cooling at 95°F (BTU/h) | 9100 |
| Rated heating at 5°F (BTU/h) | 11500 |
| SEER2 | 30 |
| HSPF2 | 11.2 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 10 |
| Maximum overcurrent protection (A) | 15 |
KW12XQ29S1DO
| Outdoor | KW12XQ29S1DO |
|---|---|
| Indoor | KW12XQ29S1DI |
| Rated cooling at 95°F (BTU/h) | 12000 |
| Rated heating at 5°F (BTU/h) | 12200 |
| SEER2 | 29.5 |
| HSPF2 | 10 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 10 |
| Maximum overcurrent protection (A) | 15 |
KW18XQ29S1DO
| Outdoor | KW18XQ29S1DO |
|---|---|
| Indoor | KW18XQ29S1DI |
| Rated cooling at 95°F (BTU/h) | 18000 |
| Rated heating at 5°F (BTU/h) | 18000 |
| SEER2 | 27.5 |
| HSPF2 | 10 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 20 |
| Maximum overcurrent protection (A) | 25 |
KW24XQ29S1DO
| Outdoor | KW24XQ29S1DO |
|---|---|
| Indoor | KW24XQ29S1DI |
| Rated cooling at 95°F (BTU/h) | 24000 |
| Rated heating at 5°F (BTU/h) | 24000 |
| SEER2 | 27 |
| HSPF2 | 10 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 25 |
| Maximum overcurrent protection (A) | 30 |
Charmo
KW09HQ19CDO
| Outdoor | KW09HQ19CDO |
|---|---|
| Indoor | KW09HQ19CDI |
| Rated cooling at 95°F (BTU/h) | 9100 |
| Rated heating at 5°F (BTU/h) | 7600 |
| SEER2 | 20.5 |
| HSPF2 | 8.8 |
| Power supply | 208–230V1Ph60Hz |
KW12HQ19CDO
| Outdoor | KW12HQ19CDO |
|---|---|
| Indoor | KW12HQ19CDI |
| Rated cooling at 95°F (BTU/h) | 12000 |
| Rated heating at 5°F (BTU/h) | 9100 |
| SEER2 | 19 |
| HSPF2 | 8.5 |
| Power supply | 208–230V1Ph60Hz |
KW18HQ19CDO
| Outdoor | KW18HQ19CDO |
|---|---|
| Indoor | KW18HQ19CDI |
| Rated cooling at 95°F (BTU/h) | 18000 |
| Rated heating at 5°F (BTU/h) | 12100 |
| SEER2 | 20 |
| HSPF2 | 8.5 |
| Power supply | 208–230V1Ph60Hz |
KW24HQ19CDO
| Outdoor | KW24HQ19CDO |
|---|---|
| Indoor | KW24HQ19CDI |
| Rated cooling at 95°F (BTU/h) | 24000 |
| Rated heating at 5°F (BTU/h) | 15700 |
| SEER2 | 19 |
| HSPF2 | 8.5 |
| Power supply | 208–230V1Ph60Hz |
Clivia
KW09XQ25S1DO
| Outdoor | KW09XQ25S1DO |
|---|---|
| Indoor | KW09XQ25S1DI |
| Rated cooling at 95°F (BTU/h) | 9100 |
| Rated heating at 5°F (BTU/h) | 9500 |
| SEER2 | 26 |
| HSPF2 | 10.4 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 10 |
| Maximum overcurrent protection (A) | 15 |
| Indoor dimensions in W H D | 32 61/64 ×11 17/32 ×7 7/8 |
| Outdoor dimensions in W H D | 31 37/64 ×21 27/32 ×13 25/32 |
KW12XQ25S1DO
| Outdoor | KW12XQ25S1DO |
|---|---|
| Indoor | KW12XQ25S1DI |
| Rated cooling at 95°F (BTU/h) | 12000 |
| Rated heating at 5°F (BTU/h) | 11000 |
| SEER2 | 24.5 |
| HSPF2 | 9.5 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 10 |
| Maximum overcurrent protection (A) | 15 |
| Indoor dimensions in W H D | 32 61/64 ×11 17/32 ×7 7/8 |
| Outdoor dimensions in W H D | 31 37/64 ×21 27/32 ×13 25/32 |
KW18XQ25S1DO
| Outdoor | KW18XQ25S1DO |
|---|---|
| Indoor | KW18XQ25S1DI |
| Rated cooling at 95°F (BTU/h) | 18000 |
| Rated heating at 5°F (BTU/h) | 14600 |
| SEER2 | 24.5 |
| HSPF2 | 9 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 16 |
| Maximum overcurrent protection (A) | 20 |
| Indoor dimensions in W H D | 39 3/32 ×12 1/4 ×8 47/64 |
| Outdoor dimensions in W H D | 37 23/32 ×25 63/64 ×15 53/64 |
KW24XQ25S1DO
| Outdoor | KW24XQ25S1DO |
|---|---|
| Indoor | KW24XQ25S1DI |
| Rated cooling at 95°F (BTU/h) | 22000 |
| Rated heating at 5°F (BTU/h) | 18000 |
| SEER2 | 23.5 |
| HSPF2 | 9 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 22 |
| Maximum overcurrent protection (A) | 30 |
| Indoor dimensions in W H D | 39 3/32 ×12 1/4 ×8 47/64 |
| Outdoor dimensions in W H D | 37 23/32 ×25 63/64 ×15 53/64 |
Polaris
KWP09R32C3O
| Outdoor | KWP09R32C3O |
|---|---|
| Indoor | KWP09R32C3I |
| Rated cooling at 95°F (BTU/h) | 9100 |
| Rated heating at 5°F (BTU/h) | 13000 |
| SEER2 | 26.5 |
| HSPF2 | 10.6 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 13 |
| Maximum overcurrent protection (A) | 15 |
| Outdoor dimensions in W H D | 34-3/8 ×21-27/32 ×14-51/64 |
KWP12R32C3O
| Outdoor | KWP12R32C3O |
|---|---|
| Indoor | KWP12R32C3I |
| Rated cooling at 95°F (BTU/h) | 12000 |
| Rated heating at 5°F (BTU/h) | 13700 |
| SEER2 | 25.5 |
| HSPF2 | 10 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 13 |
| Maximum overcurrent protection (A) | 15 |
| Outdoor dimensions in W H D | 34-3/8 ×21-27/32 ×14-51/64 |
KWP18R32C3O
| Outdoor | KWP18R32C3O |
|---|---|
| Indoor | KWP18R32C3I |
| Rated cooling at 95°F (BTU/h) | 18000 |
| Rated heating at 5°F (BTU/h) | 16500 |
| SEER2 | 24.5 |
| HSPF2 | 9.5 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 16 |
| Maximum overcurrent protection (A) | 20 |
| Outdoor dimensions in W H D | 37-23/32 ×25-63/64 ×15-53/64 |
KWP24R32C3O
| Outdoor | KWP24R32C3O |
|---|---|
| Indoor | KWP24R32C3I |
| Rated cooling at 95°F (BTU/h) | 22000 |
| Rated heating at 5°F (BTU/h) | 20400 |
| SEER2 | 25 |
| HSPF2 | 9.5 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 22 |
| Maximum overcurrent protection (A) | 30 |
| Outdoor dimensions in W H D | 37-23/32 ×25-63/64 ×15-53/64 |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
Discuss R32 single-zone ductless mini-splits with Climate Experts
R32 multi-zone ductless systems
Climate Experts checks the room-by-room loads and an approved indoor combination before selecting a multi-zone outdoor unit. We compare the combined winter output with simultaneous room demand and review how the system behaves when only one small room calls, so connecting more indoor capacity does not create an assumption of more available heat.
Read specifications, model data and selection notes
| Controls | Room controls depend on indoor style; indoor units powered by outdoor. Verify permitted combination and wiring in manual. |
|---|---|
| Limited warranty — conditions apply | KM48 submittal: standard7-year parts/compressor,registered12-year parts/compressor,terms apply. Confirm certificate and registration for each installed model; labour separate. |
KM18X6O
| Outdoor | KM18X6O |
|---|---|
| Zones | 2 |
| All ductless rated cooling BTU/h at95F | 18000 |
| All ductless heating BTU/h at5F | 13800 |
| All ductless SEER2 | 21 |
| All ductless HSPF2 | 10 |
| All ducted max heating BTU/h at5F | 13600 |
| All ducted SEER2 | 18 |
| All ducted HSPF2 | 8.1 |
KM24X6O
| Outdoor | KM24X6O |
|---|---|
| Zones | 2–3 |
| All ductless rated cooling BTU/h at95F | 24000 |
| All ductless heating BTU/h at5F | 21600 |
| All ductless SEER2 | 21 |
| All ductless HSPF2 | 10 |
| All ducted max heating BTU/h at5F | 21600 |
| All ducted SEER2 | 18 |
| All ducted HSPF2 | 8.1 |
KM30X6O
| Outdoor | KM30X6O |
|---|---|
| Zones | 2–4 |
| All ductless rated cooling BTU/h at95F | 28400 |
| All ductless heating BTU/h at5F | 27000 |
| All ductless SEER2 | 21 |
| All ductless HSPF2 | 10 |
| All ducted max heating BTU/h at5F | 26000 |
| All ducted SEER2 | 18 |
| All ducted HSPF2 | 8.1 |
KM36X6O
| Outdoor | KM36X6O |
|---|---|
| Zones | 2–4 |
| All ductless rated cooling BTU/h at95F | 36000 |
| All ductless heating BTU/h at5F | 36000 |
| All ductless SEER2 | 21 |
| All ductless HSPF2 | 10 |
| All ducted max heating BTU/h at5F | 33000 |
| All ducted SEER2 | 18 |
| All ducted HSPF2 | 8.1 |
KM42X6O
| Outdoor | KM42X6O |
|---|---|
| Zones | 2–5 |
| All ductless rated cooling BTU/h at95F | 42000 |
| All ductless heating BTU/h at5F | 37800 |
| All ductless SEER2 | 21 |
| All ductless HSPF2 | 10 |
| All ducted max heating BTU/h at5F | 36000 |
| All ducted SEER2 | 18 |
| All ducted HSPF2 | 8.1 |
KM48X6O
| Outdoor | KM48X6O |
|---|---|
| Indoor category | All Ductless |
| Rated cooling BTU/h | 48000 |
| Rated heating BTU/h at47F | 48000 |
| Rated heating BTU/h at17F | 44500 |
| Rated heating at 5°F (BTU/h) | 37800 |
| SEER2 | 21 |
| HSPF2 | 10 |
| Power supply | 208–230V1Ph60Hz |
| Minimum circuit ampacity (A) | 30 |
| MOP A | 45 |
| Heating operating range C | -30 – 24 |
Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.
Discuss R32 multi-zone ductless systems with Climate Experts
“Up to” ratings are family maximums for specific tested combinations. They do not apply to every size or indoor match. An operating-temperature limit is not a guarantee of full heating capacity at that temperature. Your proposal confirms the selected equipment and applicable ratings.
Ductless comfort, central cooling or a complete heat-pump system
Start with the problem you want to solve. A warm upper floor or rear addition may suit a dedicated ductless system. Several rooms may call for a multi-zone layout. A whole-home replacement starts with the ducts, airflow and existing furnace or air handler. We compare these approaches before selecting an outdoor unit.
King Home central air conditioners
We also sell King Home central air conditioners. Your cooling proposal identifies the actual air-conditioner model, compatible coil and indoor blower, controls and rated capacity. The heat-pump model examples above describe equipment that can heat and cool; they are not presented as model numbers for a cooling-only air conditioner.
Older Toronto homes and renovations
For a radiator home, ductless cooling can be planned alongside the existing boiler. In a renovation, we review indoor-unit locations, line routes, drainage and access while the layout can still change. For winter heat, we use the home’s heat loss and the selected model’s low-temperature output to decide whether supplemental or backup heating is needed.
Explore ductless heating and cooling, central air conditioning, heat-pump installation and our Toronto services.

Get a clear, written quote for your King Home system.
Free in-home assessment · Financing available through Financeit · Ask us about current rebates and manufacturer offers.
King Home warranty: equipment coverage and labour
Coverage depends on the exact equipment, Canadian certificate, installation and registration. Parts, heat exchangers, equipment replacement and labour are separate benefits. Read the family-specific terms above; our written proposal identifies the coverage for your selected system.
King Home offers and rebate planning
Ask us to check current manufacturer or distributor offers and rebate eligibility for the exact proposed system. We confirm the applicable program, qualified match, purchase and installation dates, and any application requirements before including an incentive in your quote.
Ontario heat-pump rebate planning · Speak with our local King Home team
Your King Home system, supported by a local team
Climate Experts was founded by Cody Johnson in 2012. Cody brings 20 years of HVAC experience, with G2, 313D and 308R licences. Our shop is at Unit 13, 905 Dillingham Rd, Pickering. We serve Durham Region and Toronto, with emergency service evenings and weekends.
See our team, our work and customer reviews. Compare Daikin, Mitsubishi Electric and all the brands we install.
Our customers. Our community.
Proud of our work. Grateful for your reviews.
Our five-star customer reviews are a source of pride for Climate Experts. We want the experience behind our name to reflect the care we put into the work.
King Home questions homeowners ask
Still have a question?
Call 905-492-7171 and tell us what you need. Our team will explain the next step and confirm availability.
Do you sell King Home ductless, air conditioners and heat pumps?
Yes. Climate Experts sells and installs all three categories in Pickering, Durham Region and Toronto. Your proposal identifies the specific Canadian model and the complete equipment match.
Can King Home ductless work in an older Toronto home?
A ductless system can add cooling and targeted heating without extending central ducts. We assess the rooms, outdoor placement, refrigerant routes and condensate drainage, including homes that retain a boiler and radiators.
What is the difference between Ultranixx and Ultranixx Eco?
They are different product families with different operating ranges and performance. We compare the selected model’s cold-weather output, indoor equipment and controls against your heating load, rather than assuming the same winter capability.
Can a King Home heat pump work with my existing furnace?
A compatible furnace-and-coil arrangement may support hybrid heating. We check the furnace, airflow, coil match, electrical supply and controls, and agree how heating switches between the heat pump and furnace.
Does the King Home warranty include labour?
Published parts and compressor coverage should not be treated as labour coverage. We confirm the selected model’s registration requirements and any separately quoted Climate Experts labour or Maintenance 365 Plus protection in writing.
Will the system qualify for a rebate?
Eligibility depends on the current program, your home and the exact rated equipment combination. Ask us to check the requirements before you order; a brand name alone does not establish eligibility.
Your next step
Talk to a Climate Expert about King Home
Tell us where you live, the equipment you have and the rooms you want to improve. We will discuss the assessment and system options for your home.
Emergency? Call 905-492-7171. Emergency service is available after hours, evenings and weekends.